PlasmaZones 2.8.5
2 changes, released April 10, 2026.
Fixed
- Master window balloons to 100% on notifications: Whenever a Plasma notification popup appeared, KWin briefly reported a tiled window as minimized and restored it a millisecond or two later. PlasmaZones retiled without that window, so the master filled the screen for a moment and then shrank back, on every notification. Two changes fix it. Plasma’s own shell surfaces, such as notifications, the emoji picker, and KRunner, are no longer tracked for tiling. A minimize also has to last 75 ms before PlasmaZones acts on it, which a real minimize always does. (#271)
- Cannot re-enable PlasmaZones from settings after killing a terminal-run daemon: When users ran
plasmazonesdmanually for log collection, systemd’s managed instance lost the D-Bus name race and exited.Restart=on-failureretried untilStartLimitBurstwas exhausted, leaving the unit wedged infailedstate.systemctl --user startthen silently did nothing until logout.DaemonController::startDaemonnow chainsreset-failed→startso the settings toggle recovers the unit automatically. (#271)